More information about the reaction criteria ( defined in mod_ReactionCriteria.f90 ).
.
More information about the reaction criteria ( defined in mod_ReactionCriteria.f90 ).
.
It is necessary to define a set of reaction criteria for :
By default, the object is switiched off with type_reaction = off_rc
Both association rates and a limited docking simulations can be performed at the same time, but the rules for recording the complexes are simplified
The reaction criteria input file consists of a set of definitions like :
#keyword criteria for solute 1 | distance| criteria for solute 2 CNONS ATOM 540 OE2 GLU A 60 26.527 32.135 -0.455 | 60.00| ATOM 332 N LEU D 34 28.306 33.610 1.176
They consist of a keyword of 5 letters, an non read block of X letter, the position of the reaction criteria of the solute 1, the distance criteria, a non-read block and the position of the reaction criteria of the solute 2
If solutes are not flexible, only the position of the atoms are read from the line. Otherwise the atom number is read and stored. And then the position of the atoms, for each conformation, will be read from the pdb input file.
Docking simulations need to define a set of reaction criteria with keywords :
All theses requirements must be met for the complex to be accepted and recorded in the complex file. For example, if you define two specific reaction criteria, three non-specific reaction criteria, and set nnnons to two. The two defined specific criteria, and at least two of the non-specific criteria, must be met for a complex to be recorded.
Association rate calculations will record the number of contacts which is formed at some distance.
You specify in the GROUP RateCalculation the maximum number of contacts with the keyword nb_contact in the sda input file,
and the distance in defining the distance of the closest window ( first_window ), the number of windows ( nb_window ) and the width of the windows ( width_window ).
All theses parameters are stored as data members of mod_rate_calculation::association_rate
In this case you can still record complexes but all reaction criteria are considered as non specific ( CNONS ).
Only the complexes which satisfy both :
Additionaly some pairs of independent contacts can be defined with the dind parameter.
If 2 reaction criteria of the same solute are at a distance smaller than dind, only 1 reaction will be considered.
You can see in reaction_criteria.log, how many of the criteria are considered as independent.